Controller Operating Instructions for IP X9K Rain Test

In the realm of environmental testing, Particularly for equipment designed to withstand harsh conditions, The IP X9K rain test plays a crucial role in determining the resilience of products against high-pressure and high-temperature water jets. Central to conducting a successful IP X9K rain test is the controller, Which orchestrates the entire testing process from start to finish. This guide explores in detail the controller operating instructions for IP X9K rain tests, Ensuring a comprehensive understanding of its functionalities, settings, and applications.

The IP X9K test is a specialized procedure aimed at assessing the water resistance of products against intense jets of water. It is particularly relevant in industries where equipment reliability in extreme weather conditions is paramount. The “IP” stands for “Ingress Protection,” and the number following it denotes the level of protection against solid objects (first digit) and water ingress (second digit). In the case of IP X9K, The focus is on the highest level of water protection, specifically against high-pressure jets.

As industries continue to demand higher standards of durability and reliability, The IP X9K rain test controller stands as a vital tool in the pursuit of excellence in product performance and longevity. Mastering the controller operating instructions for IP X9K rain tests is pivotal for conducting rigorous and reliable environmental testing. By leveraging its advanced features and user-friendly interface, Operators can achieve accurate simulations of high-pressure water ingress scenarios, ensuring products withstand the toughest real-world conditions.

[Figure 2-1] Main Screen
[Figure 2-1] Main Screen
Home Screen
Item Description and Comment
IPX9K Click to enter the IP X9K screen.
FUNC SET Includes six parts: language selection, startup mode, backlight time, lock button, user password, and touch screen calibration.
DI HIS View historical fault information.
RESERVE System time setting, appointment time setting.
Version Number The IP X9K rain chamber’s controller version number.
System Time Displays the time of the current system, The current time can be set and change on reservation setting screen.
▶ Select IP X9K test in [Main Screen] to switch to the IP X9K test screen. IP X9K Test
Figure [3-1] Fixed Value Test Screen
Figure [3-1] Fixed Value Test Screen
Item Description and Comment
① MAIN Switch to the Home screen.
② TEMP, FLOW Temperature PV Display: Displays the current temperature measurement value.
Set Value: Displays the current temperature set value (settable).
Power Value: Displays the output power at the current temperature.
③ TEST TIME The test time can be set.
④ Run Signal Displays the current test running signal.
☞If the number turns red, it means the signal is running (corresponding to the relay action).
⑤ RUN TIME Displays the running time of the current test.
☞If a fixed time is set, the remaining time of the test will be displayed below
⑥ TIME, STOP Displays the current system date and time.
Test running: indicates that the current test is running.
Test stopped: indicates that the current test is stopping.
⑦ SET Click to enter the fixed value setting screen. For detailed settings, please refer to [2.1]
⑧ HEAT Click this button and the water inside the tank starts heating
⑨ START/STOP White font shows running, which means the test is stopped. Red font shows stop, which means the test is running.
☞ Lighting button – click the lighting button to turn on the window light (this function is hidden by default and needs to be turned on in the internal parameter initialization settings)
Figure [3-2] Standby Setting
Figure [3-2] Standby Setting
Standby Setting
Item Content Description
BACK Returns the set setting.
WAIT MODE  Standby setting switch.(Factory default shutdown)
☞ Standby setting select on to set the temperature area.
TEMP ZONE Set the water temperature in the standby area.(Factory default value is 0.00)
FLOW ZONE Set the water flow in the standby area.(Factory default value is 0.00)
Figure [4-1] Operation Settings (1)
Figure [4-1] Operation Settings (1)
Operation Settings
Item Content Description
LANGUAGE Choose from Chinese or English.
POWER MODE Set the power-on operation after a power outage.
☞ Stop: After a power outage during operation, the state is restored to the operation stop state when the power is restored.
☞ Cold start: After a power outage during operation, the operation is restarted when the power is restored.
☞ Hot start: After a power outage during operation, the state is restored to the state before the power outage when the power is restored.
LIGHT OFF Backlight time setting, if set to 0, the screen will never go out.
KEYLOCK When the lock is on, all parameter settings are unavailable.
Figure [4-2] Operation Settings (2)
Figure [4-2] Operation Settings (2)
② TOUCH CALIBRATION: Touch screen calibration
Click alarm record on the main screen to reach this screen and view the machine alarm history. Alarm and History
Figure [5-1] Machine Alarm History
Figure [5-1] Machine Alarm History
Item Content Description
No Fault record number.
ALARM NAME Display the fault name.
START TIME Displays the time when the failure was started.
END TIME Displays the time when the failure has ended.
FIND Look for a certain history.
EXP Export a certain history record.
DEL Delete the history.
Figure [6-1] Appointment Settings
Figure [6-1] Appointment Settings
Appointment Time
Item Content Description
SYSTEM TIME Set the system time.
RESERVE TIME Set the time you want to reserve.
RESERVE MODE Set whether to use the reservation function.
☞ After setting the appointment, During the program test, The corresponding timing will be displayed as shown in the red highlighted part in the figure below.
Figure [6-2] Appointment and Test
Figure [6-2] Appointment and Test
① Digital input dedicated box Appendix Note
① Digital input dedicated box
② Set the input box of the program experiment name and the DI fault name
② Set the input box of the program experiment name and the DI fault name
③ When when beyond the set range
③ When when beyond the set range
④ Pop-up box
④ Pop-up box

Controller Operating Instructions for IP X9K Rain Test ISO 20653|In the realm of environmental testing, Particularly for equipment designed to withstand harsh conditions, The IP X9K rain test plays a crucial role in determining the resilience of products against high-pressure and high-temperature water jets. Central to conducting a successful IP X9K rain test is the controller, Which orchestrates the entire testing process from start to finish. This guide explores in detail the controller operating instructions for IP X9K rain tests, Ensuring a comprehensive understanding of its functionalities, settings, and applications. Read more…

IPX9K and IP9K Rain Test Chamber | ISO 20653 and IEC 60529|The engineer always use the IPX9K and IP9K rain test chamber for machine’s shell waterproof protection test. IPX9K keeps the powerful high temperature water jets. IPX9K rain test chamber applicable standard such as ISO 20653 Road vehicles — Degrees of protection (IP-Code) — Protection of electrical equipment against foreign objects, water and access. IPX9K rain test chamber compatible standard: DIN 40 050-9 – Road Vehicles; Degrees of Protection (IP Code); Protection against foreign objects, water and access electrical equipment. IPX9 rain test chamber applicable standards. Read more…

Precautions and Instructions for IP X9K Rain Test Chamber Using|Congratulations on acquiring your IP X9K rain test chamber from Wewon Environmental Chambers Co., Ltd. This cutting-edge testing solution empowers you to evaluate the water resistance of your products with precision and reliability. To ensure optimal performance and safety, We urge you to carefully follow the instructions outlined in this comprehensive user manual. Read more…