The Guidance and Operation Steps for Environmental Chamber Testing

Environmental chamber testing simulates the diverse environmental conditions that products may encounter during their lifecycle. These simulations help in assessing the impact of extreme temperature, humidity, and other environmental factors on the physical and chemical properties of materials and components. Whether it’s for electronic devices, automotive parts, or pharmaceuticals, Environmental test chambers offer a controlled setting to predict product behavior in real-world settings.

In the world of product testing and development, Ensuring the durability and reliability of your products under various environmental conditions is paramount. This is where environmental chamber testing becomes a vital tool for researchers and manufacturers alike. In this comprehensive guide, We’ll delve into the fundamentals of environmental chamber testing, Exploring everything from the basic operation steps to the myriad of applications it serves across industries.

Environmental chamber testing is a cornerstone in the product development and quality assurance processes across numerous industries. By following the proper guidance and operation steps, Businesses can leverage these powerful tools to enhance product reliability, meet regulatory standards, and ultimately, achieve customer satisfaction. Whether you’re renting, purchasing, or building your own environmental test chamber, The key is to focus on accurate, Relevant testing that mirrors the conditions your products will face in the real world.

Environmental Chamber Testing
Equipment Model TH-W2000-S TH-W4850-E
Testing Volume 2000 Liters 4850 Liters
Temperature Range -60℃~ +150℃ -70℃~ +150℃
Humidity Range 20% ~ 95% 20% ~ 98%
Temp Uniformity ±0.5~ ±1.0℃ ±0.5~ ±1.0℃
Heating Rate 2℃~ 3℃/min 2℃~ 5℃
Cooling Rate 1℃~ 2℃/min 1℃~ 2℃
Refrigerant System R449A R508A R449A R508
Compressor Tecumseh (France) Bizter (Germany)
Noise Level (dB) 65 dB 68 dB
Inner Size (W*D*H) 2000x1000x1000 1800x1800x1500
Outer Size (W*D*H) 2240x1550x1700 2000x3250x2000
Gross Weight 1950 KGS 4850 KGS

In addition to ensuring the quality and reliability of products, Mastering environmental chamber testing fosters a culture of sustainability within industries worldwide. The ability to subject products to various environmental conditions not only validates their performance but also aligns with the growing demand for eco-conscious manufacturing practices. Environmental chamber testing empowers businesses to assess the ecological impact of their products, Enabling them to make informed decisions regarding materials, Production processes, and energy consumption.

By integrating sustainability into the testing phase, Companies can reduce their carbon footprint and contribute to the preservation of natural resources. Embracing environmentally responsible testing methodologies not only benefits the planet but also enhances brand reputation and cultivates consumer trust. Through meticulous adherence to environmental standards and continuous innovation, businesses can pave the way for a more sustainable future while delivering unparalleled value to their customers|Steps for Environmental Chamber Testing:

Begin by clearly defining the purpose and objectives of the environmental chamber test. Identify the environmental conditions and parameters relevant to your product and its intended application. 1. Define Testing Objectives:
Choose an environmental test chamber that aligns with your testing requirements in terms of size, temperature range, humidity control, and other relevant parameters. Environmental test chamber rental services offer flexibility and cost-effectiveness, especially for one-time or occasional testing needs. 2. Select the Right Chamber:
Properly prepare the test samples according to the testing standards and protocols. Ensure that the samples are representative of the actual product or component being tested|Wewon Environmental Chambers Co., Ltd. Copyright 3. Prepare Test Samples:
Configure the environmental chamber settings to replicate the desired test conditions accurately. This may include adjusting temperature, humidity levels, pressure, airflow, and illumination as per the testing requirements. 4. Set Testing Parameters:
Follow the prescribed test procedures meticulously, monitoring the chamber’s performance and sample behavior throughout the testing duration. Document any deviations or anomalies observed during the test. 5. Execute Test Procedures:
Record relevant data such as temperature variations, humidity levels, product responses, and any observed abnormalities during the test. Utilize data acquisition systems or software to streamline data collection and analysis processes. 6. Collect and Analyze Data:
Analyze the collected data to evaluate the product’s performance and compliance with specified criteria or standards. Identify any weaknesses or areas for improvement based on the test results. 7. Interpret Test Results:
Prepare comprehensive test reports documenting the testing procedures, results, observations, and conclusions drawn. Include relevant graphs, charts, and statistical analyses to support your findings. 8. Generate Test Reports:
Environmental Chamber Testing
Environmental Chamber Testing Photos Environmental Chamber Testing Photos Environmental Chamber Testing Photos Environmental Chamber Testing Photos
R404A is a chlorine-free, non-azeotropic mixed refrigerant, which is a colorless gas at room temperature and pressure, and is a compressed liquefied gas stored in a cylinder. R404A has the characteristics of clean, low toxicity, non-flammability, and good refrigeration effect. R404A
R404A is often used in cold storage, food freezing equipment, marine refrigeration equipment, industrial cryogenic refrigeration, commercial cryogenic refrigeration, transportation refrigeration equipment (refrigerated trucks, etc.), refrigeration condensing units, supermarket display cabinets and other refrigeration equipment.
Similar applications as R404A, The R507 freon is a chlorine-free azeotropic refrigerant mixture, which is a colorless gas at room temperature and pressure, and is a compressed liquefied gas stored in a cylinder|Wewon Environmental Chambers Co., Ltd. Copyright R507A
Main Uses: R507 has the characteristics of clean, low toxicity, non-combustible, good refrigeration effect, etc., and is often used in cold storage, food freezing equipment, marine refrigeration equipment, industrial cryogenic refrigeration, commercial cryogenic refrigeration, refrigerated trucks, refrigeration condensing units, supermarket display cabinets and other refrigeration equipment.
Main Uses: R449A refrigerant is an HFO refrigerant, which is mainly used to replace R22, R404a, R507 and R407 series refrigerants|Physicochemical Properties: R449A is a partial mixture of R32, R125, R1234yf and R134a R449A
R449A refrigerant is used in volumetric, direct expansion, medium temperature commercial and industrial refrigeration systems, such as supermarkets (parallel units, distributed systems, small cold storages, freezers, pantry rooms, etc.), food industry (condensing units, etc.), cold chain storage, independent built-in systems, etc.
Main Uses: The R23 freon is mainly used in environmental test chambers (thermal shock test chambers), freeze dryers, ultra-low temperature refrigerators or freezers, blood bank refrigerators, biochemical test chambers and other cryogenic equipment (including scientific research refrigeration, medical refrigeration, etc.), The R23 freon mostly used in the low temperature level of these cascade refrigeration systems. R23
R508A is a chlorine-free azeotropic mixed refrigerant, which is a colorless gas at room temperature and pressure, and is a compressed liquefied gas stored in a cylinder. The R508A can be refrigerated to -80°C or even lower, making it a long-term replacement for the industry-standard R-13, R-503 and R-23 and is fully adapted to the R-503 operating environment. R508A
Main Uses: R508A has the characteristics of clean, low toxicity, non-flammability, good refrigeration effect, etc., and is mainly used in environmental test chambers (thermal shock chambers), freeze dryers, ultra-low temperature refrigerators or freezers, blood bank refrigerators, biochemical test chambers and other cryogenic equipment (including scientific research refrigeration, medical refrigeration, etc.), which is mostly used in the low temperature level of these cascade refrigeration systems.
R-508A refrigerant, also known as R508A. R-508A is an environmentally friendly azeotropic refrigerant that completely does not contain ozone-depleting CFC and HCFC substances, and is recognized and recommended by most countries in the world as a mainstream ultra-low temperature environmentally friendly refrigerant, and is widely used in the initial installation and maintenance process of new refrigeration equipment (ultra-low temperature, cryochromia).

R-449A Low Global Warming Potential Refrigerant|New Option for Environmental Chambers

R-404A and similar refrigerants have been used in environmental simulation test chambers to enable optimum performance. However, it has been determined that they have a high global warming potential, and international agreements and regulations such as European Union Regulation No. 517/2014 and the Kigali Amendment to the Montreal Protocol aim to phase down these types of compounds. It is expected that R-404A will see a global price increase as well as reduced availability over the next few years, which is why customers need an alternative. Read More…


Freon Leak Detectors for Environmental Chambers|Helps You Quickly Find Refrigerant Leak

Freon leak detectors play a vital role in ensuring the safety and efficiency of environmental chambers. As a technical support and quality inspection engineer at Wewon Environmental Chambers Co., Ltd., I am excited to introduce the latest advancements in freon leak detection technology. In this article, we will explore the importance of these devices, their functions, and the innovative features that make them indispensable in environmental chamber applications. Read More…


Germany Weiss Technik’s Climatic Test Chambers With Eco-Friendly Refrigerants, ClimeEvent

Weiss Technik’s ClimeEvent is a world first climatic test chamber which uses a combination of eco-friendly refrigerants R449A and R469A that future proof your climate and humidity testing solution. Climatic test chambers are used for quality assurance and reliability testing in fields like the engineering, pharmaceutical, aerospace and manufacturing industries. Also known as Humidity Chambers or Thermal Chambers, a Climatic test chamber from Weiss Technik can test differing climatic zones and seasonal differences – essential in help you test that your products are able to withstand a variety of temperatures during manufacturing, transport, storage and use. Read More…


France Tecumseh Freon Type and Weight|Various Type Of Compressors With Refrigerant Gas

Thanks your purchase work for environmental chamber from Wewon Environmental Chambers Co., Ltd. You have no idea on the France Tecumseh compressor type and how many Freon has been used for your environmental chamber. Right ? Here is a teaching guidance which will help you easier understand Wewon environmental chamber. There has 80 liters, 150 liters, 225 liters, 408 liters, 800 liters, 1000 liters environmental chamber as the standard size and have a safe stock in Wewon manufacture dept. Read More…


1500 Liters Environmental Chambers, Temperature Range: -80C +150C, Tecumseh Compressor

When you get an offer for environmental chambers from your supplier, They always quote you the temperature range : -70C to +150C, Because the -70C is their MAX ability for their temperature chambers. How we supply you the environmental chambers with -80C +150C ? This is the temperature range which your current supplier can not guarantee, But we can. In fact, It’s not easy work, But we can do it ! Let me explain how we meet this technical requirement: Read More…


Environmental Chamber Freon Leakage Tester|Install Refrigerant Leakage Monitoring System

So use a stainless steel plate and cover on the window to prevent the strongly light hurt the operator’s eyes. The Freon leakage tester will help the customer away from the gas leakage risk. This is mainly for the safety of testers. Especially in some European countries, there are very strict requirements for the safety of testers. Meanwhile, There has a lock system there, In this case, Help the customer lock the door and no one can open the door during the samples inside for testing work. Read More…

Please enter your email, so we can follow up with you.