The gravity impact tester is used to simulate the cell phone during or before the battery is installed, The force of impact a battery can withstand. Whether the battery will explode and catch fire after impact. The gravity impact test machine is a good way to evaluate the safety of the battery. Gravity impact tester from Wewon Environmental Chambers Co., Ltd. comply with UN 38.3.4.6, IEC 62133, UL 1642, UL 2054 & IEC 60068-4:2000.
How to use the gravity impact tester ? The lithium ion battery gravity impact tester is tested by placing the battery sample on a flat surface. Cross a rod with a diameter of 15.8 mm and place it in the center of the sample, A weight of 9.1 kg or 10 kg was used to fall from a certain height (610 mm or 1000 mm) onto the sample. Observe and evaluate the performance and safety of the battery tested by free fall test. For lithium ion batteries performance test, the most commonly used test standard is UN 38.3.4.6
The cylindrical or prismatic cell shall have its longitudinal axis parallel to the plane and perpendicular to the center of the horizontal specimen so that the curved body longitudinal bearing with a diameter of 7.9 mm shall be impacted. The prismatic cell is also rotated 90° around its vertical axis so that its wide and narrow sides can withstand impact. Each sample battery should withstand only one shock, and each test should use different samples. Coin-type or button-type battery shall make the surface of the test sample parallel to the plane. The curved body with a diameter of 7.9 mm lies across the center of the battery.




| Equipment Model | WEW-GIT-UL-1008 |
| Weight of Falling Ball | 9.1 kg ±0.46kg or 10 kg |
| Impact Height | 25mm ~1000mm (limit can be adjusted freely) |
| Impact Mode | Lift the falling ball to a certain height and release it. |
| Horizontal Bar | 15.8mm or 7.9mm Steel Bar |
| Inner Box Material | SUS#304 stainless steel plate |
| External Dimension | Galvanized cold plate baking paint treatment |
| Upgrade Mode | Electric Upgrade |
| Battery Test Samples | 200*200*200mm |
| Appearance Size | W720mm ×H1870mm × D780mm |
| Exhaust Port | Located at the back of the case 120mm |
| Test Room Door | Single door, Double layer |
| Upper Lower Impact Surface | Stainless Steel Plate |
| Power Source | 1∮, AC220V, ф5A |
| Equipment Weight | About 145 kg︱Filling Material:Glass Wool |
| Protective Device | Upper and lower protection switch, safety bolt |
This battery impact testing machine adds a guided drop-weight configuration to our gravity impact tester range. An electric lifting mechanism raises the weight before release. During testing, the weight strikes a steel bar positioned across the cell, applying a localized mechanical impact. The test helps evaluate whether mechanical abuse leads to hazardous cell failure under the selected test procedure.
The vertical guide tube helps limit sideways movement of the drop weight, while its observation slot provides a view of the moving assembly. At the sample platform, two slotted supports position the steel bar across the cell and allow it to move downward during impact. This arrangement supports consistent sample setup and alignment between the drop weight, steel bar and test cell. Motor, mechanical assembly and electrical controls in the upper compartment of the battery impact tester
|
Maintenance Matters |
Sample selection depends on both the specified test method and the machine’s usable fixture space. Typical applications include cylindrical lithium-ion cell impact testing, with other cell formats assessed against the applicable standard. A cell that physically fits inside the chamber is not automatically an appropriate specimen for every impact test.
For UN 38.3 T.6 impact testing, the relevant specimens are cylindrical cells with a design diameter of at least 18.0 mm. Other specified cell formats follow the T.6 crush procedure instead. UL 1642 applications also require attention to cell construction: its revised requirements use a round-bar crush test in place of the impact test for soft-case pouch cells. Equipment configuration should therefore be selected against the customer’s required standard, edition and test clause.
| The gravity impact test machine must be placed on a stable table before use;Do not operate the machine in use;The machine must be well ventilated when working. | Directions For Use |
| Select the corresponding power voltage, do not be too high, to avoid burning the gravity impact tester. | |
| In case of any abnormality of the instrument, please contact the institute for timely treatment. | |
| Key mechanical components, due to the large operating load, please timely add lubricating oil to the mechanical part. | |
| After each test, clean the machine and keep it clean. Please wipe the control box with dry cloth instead of wet cloth. | |
| This gravity impact test chamber has the function of power failure protection, preventing the sudden power failure from accidental impact and the operation of the wrong action to protect personal safety. | Equipment Characteristics |
| The height control adopts the function of micro switch to automatic stop. Safe, practical and reliable. | |
| The gravity impact test chamber adopts box-type explosion-proof design, which is beautiful and economical in appearance | |
| The bottom is equipped with a thickened buffer board. 12 mm thick explosion-proof glass can be viewed at any time. |
Guided Drop Weight and Cell Positioning Fixture
This battery cell impact tester uses an electrically lifted drop weight to apply a localized mechanical impact through a steel bar. The cell rests on the support platform, with the bar positioned across its centre. When released, the weight strikes the bar, transferring the impact to the test specimen.
The vertical guide tube helps limit sideways movement of the weight, while the observation slot provides a view of the moving assembly. Two slotted supports locate the steel bar above the sample and guide its downward movement during impact. Together, these components help maintain alignment between the weight, bar and cell.
This configuration supports cell-level mechanical abuse evaluations in battery manufacturing, independent testing and research laboratories. Suitable specimens depend on the required test method: cylindrical cells are a key application, while prismatic and coin-type cells require assessment against their applicable test requirements. Pouch cells may require a controlled crush test instead of a drop-weight impact test.
For equipment selection, provide the cell shape, dimensions, energy rating and required standard edition. We can then review the fixture clearance, support area and available drop height for your sample. Larger cells require an individual configuration review; chamber size alone does not determine test suitability.
|
UL 1642 Test Method |
This configuration is intended for cell manufacturers, battery safety laboratories, third-party testing organizations and research teams conducting cell-level mechanical abuse evaluations. Battery pack manufacturers can also use it to evaluate individual cells during supplier qualification and product development. It should be distinguished from equipment used for complete battery pack drop tests, controlled crush tests or acceleration shock tests.
Send us your cell dimensions, shape, chemistry, energy rating and required test standard when requesting a quotation. For cylindrical cells, specify the diameter and length; for prismatic cells, provide the length, width and thickness. These details allow us to confirm fixture clearance, support area, steel bar arrangement and available drop height before recommending a configuration. Larger cells require an individual assessment of both mechanical clearance and test chamber protection.